Smeg S64S Manuale di Servizio Pagina 15

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 23
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 14
Instructions for the installer
41
7.5 Regulation of primary air
Referred to distance “A” in mm.
60 cm hobs with separable control panel.
Burner
G20
20 mbar
G30/G31
28/37 mbar
Auxiliary (1) 3.0 4.0
Semirapid r (2) 1.0 2.0
Semirapid l (3) 1.0 2.0
Rapid large (4) 1.0 3.5
Ultrarapid (5) 1.0 5.0
90 cm hobs with separable control panel.
Burner
G20 G30/G31
20 mbar 28/37 mbar
Auxiliary (1) 2.5 3.0
Semirapid (2) 1.0 2.0
Rapid (3) 1.5 1.5
Fish burner (4) 0.5 8.0
Ultrarapid (5) 1.5 3.0
60 cm hob with built-in control panel.
Burner
G20 G30/G31
20 mbar 28/37 mbar
Auxiliary (1) 3.0 4.0
Semirapid r (2) 1.0 2.0
Semirapid l (3) 1.0 2.0
Rapid medio (4) 1.5 3.5
Ultrarapid (5) 1.0 4.0
To identify the burners on your hob, refer to the drawings in point “8.3/8.4 Arrangement of
burners on hob “
Vedere la pagina 14