Instructions for the installer
51
9.3 Adjustment for LPG
Unscrew screw C and push air regulator D as far as it
will go.
Using a 7-mm wrench, remove nozzle E and replace it
with the appropriate nozzle, following the instructions in
the tables for the type of gas to be used. The nozzle
tightening torque must be no more than 3 Nm.
Adjust the air by sliding regulator D until distance “X
indicated in table in “9.5 Primary air adjustment” is
reached.
Lock regulator D by tightening screw C.
9.4 Adjustment for natural gas
To reset the appliance for operation with this type of gas, carry out the same
steps as described in “9.3 Adjustment for LPG”, but select the nozzles and
adjust the primary air for natural gas as indicated in the tables in "9.2 Burner and
nozzle characteristics table” and “9.5 Primary air adjustment”. After the
adjustments have been carried out, restore the seals with sealing wax or
equivalent material.