Instructions for the installer
2.6 Gas connection
Connection to the gas mains may be made with a rigid copper pipe or
with a flexible pipe conforming to the provisions defined by UNI-CIG
7129.
After connection operations, check for leaks using a soapy solution.
The hob has been inspected for G20 natural gas (2H) at a pressure of 20
mbar. For use with other types of gas, see chapter “3. ADJUSTMENT TO
DIFFERENT TYPES OF GAS. The hose connection at the rear of the
appliance has a ½” internal thread (ISO 228-1).
Connection with rigid copper pipe:
the connection to the gas mains must
not provoke stress of any kind on the
appliance.
Connection may be made by using
biconicaladapter D with insertion of
gasket C supplied.
Connection with flexible steel pipe:
use only flexible stainless steel pipes
conforming to UNI-CIG 9891
regulations, inserting gasket C
supplied between the fitting A and the
flexible pipe B.
The flexible pipe must be installed so that pipe length does not exceed 2
meters of maximum extension. Make sure that the pipes do not touch
any moving parts or become crushed.
2.7 Connection to LPG
Use a pressure regulator and make the connection to the tank according
to the provisions of UNI-CIG 7432 and UNI-CIG 7131. Make sure that
feed pressure conforms to the levels shown in the table in paragraph “3.2
Burner and nozzle characteristics table