Instruction for the installer
9
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
Flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1 50 30 350 73 71
Semi-rapid 1.75 65 33 450 127 125
Rapid 2.5 79 45 800 181 179
Triple crown 3.5 94 65 1500 254 250
Oven 5.2 110 59 1200 377 371
Grill 4 100 // // 290 285
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary 1 72 350
Semi-rapid 1.75 97 450
Rapid 2.5 108 800
Triple crown 3.5 133 1500
Oven 5.2 164 1200
Grill 4 150 //