Smeg CIR60X3 Manuale delle Istruzioni Pagina 13

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 24
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 12
Instructions for the installer
5.3 Regulation for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for LPG, perform the same operations described in paragraph
6.2 Regulation for LPG”, but refer to the following table for the proper
injectors.
NG – 1.0 kPa
Burner
Nominal gas
consumption
(MJ/h)
Injector
(mm)
Auxiliary (1) 4.8 0.98
Semi rapid (2) 6.0 1.10
Rapid (3) 11.5 1.50
Rapid (4) 12.2 1.55
Wok (5) 15.0 1.70
15